LOADING
Question

Which of the following statements is correct about a Benson boiler?

A.

Flue gases pass only in one direction

B.

Air is sent through the same direction

C.

There is no recirculation of water

D.

Steam is sent out in multiple directions

Answer ( Option C)

There is no recirculation of water

Solution

Benson boiler is a high pressure water tube boiler.

In Benson boiler :

1. No boiler drum is used

2. No circulation of water is occur

3. It is also known as once through boiler

Hence, the correct option is (C).