In a multi machine interconnected system, subsequently to a 3-phase
fault, the transient stability is examined by
In
a 3-phase, 5 kV, 5 MVA system, what is the base impedance?
In
an n-bus power system, considering n-nodes network, the size of Ybus
The
voltage of a particular bus can be controlled by controlling the_________.
Which of the following buses are used to form bus admittance matrix for load flow analysis?
1.
Load bus
2.
Generator bus
3.
Slack bus
Equal-area criterion is employed to determine
In
differential protection of bus-bars the CT ratio
The changes in real bus power affects mainly
The size of bus admittance matrix for the sing line diagram shown in the
figure is________.
In
a power system there are 50 buses
Slack
bus = 1
Generator
buses = 8
Load buses = 41
By Newton- Raphson method, the size of the jacobian matrix =_________.
In
power system load flow studies, the quantities specified at a slack bus
are________and______.
Select
the wrong statement from the following in relation to power flow analysis
Load
frequency controllers are carried out with
For
formation of the Y bus matrix (using node voltage analysis) in power system
network modeling is used
Steady
state stability of a power system is improved by
In
Gauss-Seidel load flow method, the number of iterations may be reduced if the
correction in voltage at each bus is multiplied by
In a power system network, At which bus, the shunt is connected that can
be known from
For a graph of power system network shown in the figure below, where bus numbers and impedances are marked, assuming equal R/X of impedances, find the bus impedance matrix element Z22.
The Ybus matrix is a sparse
matrix because :
Load
flow studies must be made on a power system before
In G-S method of power flow problem, the number of iterations
What
is the form of the
For
load flow studies, what are the quantities specified at load bus?
The
per unit value of a 4 resistor at 100 MVA
base and 10 kV base voltage is
Which
of the following quantities are normally specified at the voltage controlled
bus for a load flow solution?
Which
one of the following statements is correct?
The
elements of each row of a Ybus matrix for load flow
studies in power system add up to zero.
A sample power system network is shown in the figure given below. The
reactances marked are in p.u. What is the pu value Y22 of
Consider
the following statements in respect of load flow studies in power system :
1.
Bus admittance matrix is a sparse matrix
2.
Gauss-Seidel method is preferred over Newton Raphson method for load flow
studies
3.
One of the buses is taken as slack bus in load flow studies
Which
of these statements are correct?
Consider
the following quantities :
1.
Real power
2.
Reactive power
3.
Power factor
4.
Input current
5.
Bus voltage magnitude
6.
Bus voltage phase-angle
For
the purpose of the load flow studies of a power system, each bus or node is
associated with which one of the combination of the above four quantities?
A bus bar is rated by
A
equipment has an impedance of 0.9 pu to a base of 20 MVA, 33 kV. To the base of
50 MVA, 11 kV, the pu impedance will be
The
Base impendence of the power system is given by :
A
transmission line has a reactance of 1 Pu is operating at Vs = Vr = 1pu. The generator is connected at source and which is
delivering 0.5 Pu of active power. Find the load angle
The bus bar zone faults are generally
Fault
calculations using computer program are usually done by
In Newton Raphson method, the convergence is not affected by the choice
of
Stability
of a power system can be improved by :
1.
Using series compensations
2.
Using parallel transmission lines
3.
Reducing voltage of transmission
Which
of the above statements are correct?
The Ybus
Normally Zbus
The principal information obtained from load flow studies in a power system are :
1.
Magnitude and phase angle of the voltage at each bus.
2.
Reactive and real power flows in each of the lines.
3.
Total power loss in the network.
4.
Transient stability limit of the system.
Select
the correct answer using the codes given below :
For
a load bus of a power system, the specified quantities are :
In
load flow studies, the quantities specified a generator bus of a power system
are_______.
In a power system, each bus or anode associated with how many
quantities?
For the bus admittance matrix (Ybus) of a 4-bus system given in per unit, the buses having shunt elements are________.
A
transmission line has 0.2 pu impedance on a base of 132 kV, 100 MVA. On a base
of 220 kV, 50 MVA, it will have a pu impedance of_________.
The
The relation between the old and new per unit impedance values is given by :
The bus admittance matrix of a power system is given as
The impedance of line between bus 2 and 3 will be equal to
The test used to locate high-resistance faults in low-resistance
conductor circuits is :