LOADING
Question

An ideal refrigerator maintains a temperature of -23°cwhen placed inside a room at 27°C . Heat infiltration into the refrigerator is 0.5 kJ/s. The power required to pump the heat out is:

एक आदर्श रेफ्रिजरेटर 27°C के कमरे में रखे जाने पर -23°c का तापमान बनाए रखता है। रेफ्रिजरेटर में ऊष्मा का प्रवेश 0.5 kJ/s है। ऊष्मा को बाहर निकालने के लिए आवश्यक शक्ति है:
A.

0.1 kW

B.

0.034 kW

C.

0.45 kW

D.

55 W

Answer ( Option A)

0.1 kW

Solution

Given:

Refrigerator temperature 

Room temperature 

 

Heat infiltration or to pass into the refrigerator = 0.5 kJ/s


COP of ideal Refrigerator,

Power/work input = 0.1 kW is the power required to pump the heat out.

 

Hence, the correct option is (A).