LOADING
Question
At a certain location of a plate girder of web size 1000 mm × 10 mm, a pair of bearing stiffeners 100 mm × 5 mm is welded. The effective area of bearing stiffeners is
A.
1000 mm2
B.
2000 mm2
C.
3000 mm2
D.
5000 mm2
Answer ( Option D)

5000 mm2

Solution

Total effective area = 40 × tw × tw + 2 × 100 × 5 
= 40 × 10 × 10 + 2 × 100 × 5
= 5000 mm2