LOADING
Question
The number of blows observed in a Standard Penetration Test (SPT) for different penetration depths are given as follows:
Penetration of sampler Number of blows
0-150 mm 6
150-300 mm 8
300-450 mm 10
The Standard Penetration Number (N) will be
A.
8
B.
14
C.
18
D.
24
Answer ( Option C)

18