Question
What is the approximate value of the tensile strength governed by yielding of the cross section of a roof truss diagonal 100 × 75 × 6 mm (fy = 250 MPa) connected to a gusset plate by 4-mm welds as shown in figure? [Take partial safety factor as 1.10]
 
A.
115 kN
B.
230 kN
C.
460 kN
D.
207 kN
Answer ( Option B)

230 kN