LOADING
Question
While conducting the flow measurement using a triangular notch, an error of +2% in head over the notch is observed. The percentage error in the computed discharge would be 
A.
+7%
B.
-3%
C.
+5%
D.
-4%
Answer ( Option C)

+5%

Solution

For flow measurement using triangular notch discharge, Q α H 5/2